Description
- SUIT AIR SUSPENSON
- SARN #46880 APPROVAL
Important Fitting Instructions
- Service line brake hose max length: 1.5m
(All service line lengths must be equal) - Refer to drawing for max 3/8” Blue nylon lengths
- No restrictions on all Maxi supply rubber hose & 3/8” red nylon
| 1/2” Maxi Supply Rubber Hose |
|||||||||||||||||||| | 1/2” Service Brake Rubber Hose |
| 3/8” Red Nylon Pipe |
3/8” Blue Nylon Pipe | |
3/8” Nylon to Air Bags |
BILL OF MATERIALS FOR KIT SBX101-LS-W1
NO. | PART NO. | DESCRIPTION | QTY |
01 | 12250 | Air Brake Rubber Hose 1/2" | 10 |
02 | 125-8-6 | Hose Barb 1/2" x 3/8NPT | 8 |
03 | 125-8-8 | Hose Barb 1/2" x 1/2" | 4 |
04 | 145 | Drain Valve 1/4" | 1 |
05 | 220TMP | Tank Mounting Pad | 2 |
06 | 33-A420 | Manifold Mounting Plate 1/2" | 1 |
07 | 41-022 | Hose Clamps S/Steel 1/2" | 16 |
08 | 6-500BU | Nylon Blue 3/8" | 10 |
09 | 6-500RD | Nylon Red 3/8" | 10 |
10 | 73152-12 | 3/4" Pipe Plug | 1 |
11 | 73152-8 | 1/2" Pipe Plug | 2 |
12 | 73220-12-6 | 3/4" x 3/8" Reducer | 1 |
13 | 73325-12-8S | 3/4" x 1/2" Nipple Steel | 1 |
14 | 73750-6 | 3/8" Pipe Street Tee | 1 |
15 | 968-6-8PXDOT | 3/8" x 1/2" Male Connector P/In | 2 |
16 | 968-6PXDOT | 3/8" x 1/4" Male Connector P/In | 1 |
17 | 969-6-6PXDOTS | 3/8" x 3/8" Male Elbow 90 Deg sw | 1 |
18 | 969-6PXDOTS | 3/8" x 1/4" Bsp Male Swv Elbow | 2 |
19 | AA102626 | Relay Valve R12V | 1 |
20 | AA3802 | Spring Brake Valve SR38 | 1 |
21 | CA93-20 | 1/2" Male Adaptor non sealing | 1 |
22 | CA93-85 | 1/2" Male Coupling non sealing | 1 |
23 | PWM2076 | Test Point 3/8" | 1 |
24 | 4757145000 | Load Sensing Valve Suit Air Susp | 1 |
25 | MF22-1/4R | Reducer – M22 x 1/4" | 1 |
26 | 969-6PXDOTS | 3/8" x 1/4" Bsp Male Swv Elbow | 4 |
27 | MF12-1/4A | Adaptor – M12 x 1/4" | 2 |
28 | MF16P | Plug – M16 | 1 |
29 | MF16-1/4A | Adaptor – M16 x 1/4" | 1 |
30 | MF16S | Washer – M16 | 2 |
31 | MF22S | Washer – M22 | 1 |
32 | MF12S | Washer 12mm | 2 |
33 | Jumbo | Air Tank 60LT | 1 |
34 | SB30/30SB | 30/30 Spring Brake Seal Back | 4 |
NOTE: ANY DEVIATION FROM THIS DRAWING OR KIT CONTENTS AS SUPPLIED MAY INVALIDATE ADR COMPLIANCE. RELATIVE POSITION OF VALVE/S & TANK/S ON DRAWING IS FOR GUIDANCE ONLY. VALVES MUST BE POSITIONED TO KEEP AIR LINE LENGTHS WITHIN LIMITS INDICATED.